A&D AD-4408C Manual de instrucciones Pagina 50

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 49
AD-4408C Weighing Indicator Page 48
Write command
Specify the data type to write by the command No. (RWw000E).
Place the data to write in the command data (RWw000C to RWw000D).
Fig.12 Performance of the write command
CPU normal operation
The CPU normal operation (RX0006) is a signal to check that the AD-4408C is turned
on and it functions normally. During normal operation, the signal is reversed at an
interval of 0.5 to 1 second.
Fig.13 CPU normal operation signal
Command processing reques
t
(RY0002)
Command data (RWw000C to 000D)
Read/write
response (RX0003)
Read/write request (RY0003)
Command No. (RWw000E)
Command No. response (RWr000E)
Command processing response (RX0002)
The read/write request (RY0003) is
OFF.
CPU normal operation (RX0006)
0.5 to 1 second