Page 37 AD-4408C Weighing Indicator
9.1.3. Data transfer mode
Three data transfer modes are available; stream, auto printing and manual printing.
Stream mode
Transmits data in sync with the display update rate. If
the indicator can not catch up with the update rate
because of the baud rate, the transmission is paused
until the next updating.
The transmitted data is the same as what is being
displayed. Data that is not displayed is never
transmitted.
Auto printing mode
Transmits data once only when the weight value with
5 d or greater is stable.
For another transmission, the weight value must fall
below 5 d once.
Manual printing mode
Transmits data when the F key that is assigned to
Manual print command is pressed or a command is
sent from the CC-Link master station.
9.2. CC-Link
The AD-4408C CC-Link is a remote device station of CC-Link ver.1.10. When a
CC-Link is used, the AD-4408C can be controlled by the PLC remote I/O or remote
registers. So, the program can be simple. And connection to a PLC is simple, thus, a
weighing system can be built easily. The setting values of CC-Link are changed in the
general functions CC f01 to CC f04.
Station number 1 to 64
Number of occupied stations 1 station, 2 stations, 4 stations
Baud rate 156 kbps, 625 kbps, 2.5 Mbps, 5 Mbps, 10 Mbps
Initialization Not required or required
Communications connector
The connector used can be attached or removed while the power is ON.
The function of each signal line is as follows.
DA Signal DA
DB Signal DB
DG Signal ground
SLD Shield
FG Frame ground