Vista de pagina 0
WinCT-Plus
Instruction
Manual
OP-08)
Please see the separate document "Manual(for the AD8526)" if the
A
D8526(Ethernet Converter) is used.
Ver.2.01
Mar. 21, 2008
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - Instruction

WinCT-PlusInstructionManual(OP-08)Please see the separate document "Manual(for the AD8526)" if theAD8526(Ethernet Converter) is used.Ver.2.0

Pagina 2 - Contents

9Step 7 Enter the IP address, subnet mask, default gateway and click ”Next”. It may take a while to proceed to the next screen. Step 8

Pagina 3 - (for the OP-08).PDF

10 Step 9 Click “Finish”. Step 10 Quit after verifying that the IP address has been changed. Step 11 Write down the set IP address on the IP addres

Pagina 4

11 5. Using Data Acquisition Software RsMulti5-1. Features of RsMultiThis software enables data acquisition from A&D’s electronic balances or pla

Pagina 5

125-2. Setting RsMulti Start from the Start menu on the computer. Click Start, Program, A&D WinCT-Plus, RsMulti to start. To open

Pagina 6

13 The Property window opens. Follow the steps below to set up: ①Provide a name for the connection, e.g. GH-252 (the name of the weighin

Pagina 7

14 As shown below, GH-252 is registered in the Config window. For connection of multiple instruments, click the “Add” button to add the con

Pagina 8

15 -Sending a send data command to the weighing instrument for data acquisition. Click the “Test” button to send the command s

Pagina 9

16 Step 4 Quitting communication Click the “Stop” button. Step 5 Pasting data into an Excel file (Not applicable with Windows Vista)

Pagina 10

175-4. Explanations about each function of the RsMulti (1) The RsMulti window Table ① Records received data. To change the title, doub

Pagina 11 - Step 9 Click “Finish”

18 Manual / Repeat Manual or automatic command transmission can be selected. -When “Repeat” is selected, a command will be sent automatica

Pagina 12

1Contents1. Introduction ---------------------------------------------------------------------------------------------------2. Specifications ------

Pagina 13

19Command Data This function sends the same command to all the connected instruments. -When “All” is selected, the setup command wil

Pagina 14

20(2) Config window To open, click “Open” from the Config menu in the RsMulti window. Displays the list of the connection settings. Table

Pagina 15

21(3) Property window When Connection Name is selected (highlighted), click the “Property” button to display the Config window. It can be

Pagina 16

22 -COM For COM connection, select this option button. Setup the RS232C communication settings. Port:Com: Com port (*1

Pagina 17

236. License Agreement -It is prohibited to reproduce "WinCT-Plus" without our prior written consent. -Specifications of "WinCT-Plus&

Pagina 18

247. Supplementary7-1. Using as a virtual COM port With attached software “ComPort Redirector”, the OP-08 connected to a LAN can be used as aCOM po

Pagina 19

25 (3) Click the [Add IP] button. Enter the IP address and Port number of the OP-08 and click the OK button. In the default setti

Pagina 20

26 (6) Click the [Save] button to save and then click the [Close] button to finish. (7) Now, communication with the OP-08 can be enabled by openi

Pagina 21

277-2. Using a DHCP If a DHCP server is available for the network to which the OP-08 is connected, follow theprocedures described below to change the

Pagina 22

28 Step 4. Check the “Obtain an IP address automatically” “Assign IP” buttons. Step 5. Check the DHCP box and then click the Next button.

Pagina 23

21. IntroductionThis manual describes the operation to acquire data from a balance via an OP-08 Ethernetinterface by using data acquisition software “

Pagina 24

29 Step 6 Click the Assign button. Step 7. Click the Finish button. Step 8. Click the Search button to display the IP address assigned by the DHCP.

Pagina 25

308. Verify these items if communication problems occurIn the event that the communication fails even though you conducted your set up following thein

Pagina 26

31OK button. Step 7 When the screen as shown below appears, click “Serial Settings”.

Pagina 27

32 Step 8 The current settings for serial communication will be displayed. Confirm that the settingscorrespond with those shown in the table below .

Pagina 28

33 Step 10 Click “Apply Settings” to apply the settings change. Please wait for completion. Step 11 Click “Connection” on the screen below.

Pagina 29

34 Step 12 The screen below will be displayed. Confirm that the “Local Port” is “10001.” If thesetting is different, change the setting to “10001” an

Pagina 30

35 Step 14 Click “Apply Settings” to apply the settings change. Please wait for completion. Step 15 Quit the DeviceInstaller.

Pagina 31

32. Specifications OP-08 specificationsLAN interface10Base-T / 100Base-TX(Auto recognition)Shape of connector RJ45Protocol*1TCP/IP,UDP,ARP,ICMP,SNMP,

Pagina 32 - OK button

43.Installing Each Software If it is already installed, proceed to "4.Network Setting". For windows 2000, XP or Vista, login the compute

Pagina 33

54. Network SettingTo implement a LAN connection, it is required to set the IP address, subnet mask, etc. for boththe computer and the OP-08. Please c

Pagina 34

64-1. Setting a computer Set the IP address and the subnet mask. Open the Property window of TCP/IP, select “Use the following IP addres

Pagina 35

74-2. Setting a weighing instrument and OP-08(1) Setting a weighing instrument Set the internal setting of the serial interface of the weighing ins

Pagina 36

8 Step 5 Confirm that the IP address is selected. Click the Assign IP button. If the following settingis made without selecting the IP address, the i