A&D AD-4430B Especificaciones

Busca en linea o descarga Especificaciones para De medición, control y control A&D AD-4430B. A&D AD-4430B Product specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2 - This manual and Marks

- 8 - AD-4430B 110 35.3 (2.5) 100 1.334.5 39.4 28 20°36.1 5.53.3.5. Dimensions Unit : mm Illustration 1 Dimensions

Pagina 3 - Contents

AD-4430B - 9 - 3.4. Names (The Front Panel And Rear Panel ) Illustration 2 Front panel & rear panel

Pagina 4

- 10 - AD-4430B Ex.: Shielded load cell cableEx. Power cableAccessory connectorPress the button to remove & insert it.Press button to remove &

Pagina 5 - Illustrations

AD-4430B - 11 - 4.4. Shield Cable Connect the load cell shield wire only to the shield terminal of the AD-4430B. As a general rule, No ground

Pagina 6 - 1. Compliance

- 12 - AD-4430B Type Advantages Disadvantages Description 6-wire connection (recommended) The error is small even when the load cell cable is exte

Pagina 7 - 2. Outline and Features

AD-4430B - 13 - 5. Operations 5.1. General Functions 5.1.1. Zero Adjustment Zero adjustment is a function to set the gross weight to zero. It

Pagina 8 - 3. Specifications

- 14 - AD-4430B Clearing The Tare Weight And Zero Adjustment The way to clear the tare weight and zero adjustment : While pressing and holding the

Pagina 9 - 3.3.4. Accessories

AD-4430B - 15 - 5.1.5. Customizing The Function Of the Display x Assign a function to the display x in the general functions. Functions Relat

Pagina 10 - 3.3.5. Dimensions

- 16 - AD-4430B 5.1.9. The Hold Function There are three types of hold functions which can be used for different purposes. Normal hold Holds

Pagina 11

AD-4430B - 17 - 5.2. Mode Map And Operation Switches 5.2.1. Mode Map The module has several modes to perform various operations. Perform mode s

Pagina 12 - 4. Installing The Module

This manual and Marks All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Instit

Pagina 13 - 4.4. Shield Cable

- 18 - AD-4430B 5.2.2. Operation Switches Key State Function and Use Weighing mode The display switch between gross and net in factory set

Pagina 14

AD-4430B - 19 - 5.3. Calibration 5.3.1. Outline In the calibration mode, the operation to relate the output voltage from a load cell to the mass

Pagina 15 - 5. Operations

- 20 - AD-4430B 5.3.2. The Calibration With An Actual Load (Using A Mass) Calibration is performed using a calibration weight. Before performin

Pagina 16

AD-4430B - 21 - 5.3.3. Gravity Acceleration Correction When the scale (module) has been calibrated in the same place as it is being used, gravi

Pagina 17 - 5.1.6. Memory Backup

- 22 - AD-4430B Illustration 8 Gravity Acceleration Graph 5.3.4. Outline Of The Linearization Function Even if zero and span

Pagina 18 - Averaging hold

AD-4430B - 23 - 5.3.5. The Actual Load Linearization Function Set the digital linearization by loading/unloading masses. Warm up the module f

Pagina 19 - 5.2.1. Mode Map

- 24 - AD-4430B 5.3.6. The Function Related To The Calibration Step 1 Press the + key to enter to the calibration mode and display

Pagina 20 - 5.2.2. Operation Switches

AD-4430B - 25 - Function No. Parameter and range Function name Description Default value CAL02 0 to 0.0000 Decimal point position Decimal point

Pagina 21 - 5.3. Calibration

- 26 - AD-4430B Function No. Parameter and range Function name Description Default value CAL08 0.0 to 9.9 Stability detection time Performs stab

Pagina 22

AD-4430B - 27 - Function No. Parameter and range Function name Description Default value CAL16 0 to 1 Zero setting when power is turned on Selec

Pagina 23 - Gravity Acceleration Table

AD-4430B - 1 - Contents 1. Compliance...

Pagina 24

- 28 - AD-4430B 5.3.7. The Function Related To The Linearization Function Confirm and change linearity settings. To use this function, select

Pagina 25

AD-4430B - 29 - 5.3.8. Error Codes For The Calibration When an error occurs during calibration, the error number is displayed. If calibration is

Pagina 26

- 30 - AD-4430B 5.4. General Functions In this section, the way of pre-setting and descriptions for the general functions is described. Genera

Pagina 27 - (ZERO)

AD-4430B - 31 - 5.4.2. The Adjustment Of The Digital Filter Adjust the digital filter using Fnc05 (digital filter). The available settable rang

Pagina 28

- 32 - AD-4430B 5.4.3. The List Of The Basic Functions Function No. Parameter and range Function name Description Default value Fnc01 0000 to 11

Pagina 29

AD-4430B - 33 - Function No. Parameter and range Function name Description Default value Fnc09 1 to 2 Mass to be compared with near-zero Item to

Pagina 30

- 34 - AD-4430B 5.4.5. The List Of The BCD Function Function No. Parameter and range Function name Description Default value bcd01 1 to 4 Outpu

Pagina 31

AD-4430B - 35 - 6. Interface 6.1. The Parallel BCD Output 6.1.1. Timing Chart Of The BCD Output The strobe signal, will be turned on when star

Pagina 32 - 5.4. General Functions

- 36 - AD-4430B 7. Maintenance 7.1. Error Messages If an error message is displayed, refer to the chart below to take proper measures. Error messa

Pagina 33

AD-4430B - 37 - 7.2.2. The Operation With The BCD Input When inputting "ON" level to the "DIAGNOS" terminal of the BCD input

Pagina 34 - key status

- 2 - AD-4430B 5.3.6. The Function Related To The Calibration...24 5.3.7. The Function Rel

Pagina 35

- 38 - AD-4430B 7.3. Check Mode The check mode checks the performance of the display, key switches and external I/O. 7.3.1. Entering The Chec

Pagina 36

AD-4430B - 39 - 7.3.4. Monitoring The Internal Value Internal count ( 10 times of weighing value ) is displayed. ex. If internal count is 123

Pagina 37 - 6. Interface

- 40 - AD-4430B 7.4. Initializing Parameters The initialization mode restores the parameters of the default values to the FRAM. Three types of i

Pagina 38 - 7. Maintenance

AD-4430B - 41 - 7.5. Verifying The Load cell Connections Using Multimeter The load cell connection can be checked easily using a digital multim

Pagina 39 - BCD Input

- 42 - AD-4430B When the module does not operate properly, write the required items in the table below and contact your local A&D dealer. Item

Pagina 40 - 7.3. Check Mode

AD-4430B - 43 - 7.6. The Parameter List For The Function List When performing maintenance, use the following list as a memorandum. When making in

Pagina 41

- 44 - AD-4430B Function No. Parameter and range Function name Description Default value User settingMEMOFnc09 1 to 2 Mass to be compared with ne

Pagina 42 - 7.4. Initializing Parameters

AD-4430B - 45 - 7.6.3. The List Of The BCD Function Function No. Parameter and range Function name Description Default value User settingMEMObcd

Pagina 43

- 46 - AD-4430B 7.6.4. The List Of The Calibration Function No. Parameter and range Function name Description Default value User settingMEMOCAL0

Pagina 44

AD-4430B - 47 - Function No. Parameter and range Function name Description Default value User settingMEMOCAL12 0 to 1 Output when overflow and un

Pagina 45 - 7.6.1. Basic Functions

AD-4430B - 3 - Illustrations Illustration 1 Dimensions...

Pagina 46

- 48 - AD-4430B 7.6.5. The List Of The Linearization Function Function No. Parameter and range Function name Description Default value User sett

Pagina 47

AD-4430B - 49 - 8. Dimensions Unit : mm 110 35.3 (2.5) 100 1.334.5 39.4 28 20°36.1 5.5

Pagina 48

- 50 - AD-4430B MEMO

Pagina 49

AD-4430B - 51 - MEMO

Pagina 50

- 52 - AD-4430B MEMO

Pagina 52 - - 50 - AD-4430B

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 A&D ENGINEERING, INC

Pagina 53 - AD-4430B - 51

- 4 - AD-4430B 1. Compliance 1.1. Compliance with FCC rules Please note that this equipment generates, uses and can radiate radio frequency ene

Pagina 54 - - 52 - AD-4430B

AD-4430B - 5 - 2. Outline and Features The AD-4430B has the following features. The weighing module is a weighing indicator that amplifies sig

Pagina 55

- 6 - AD-4430B 3. Specifications 3.1. Analog to Digital Unit (Load cell Input, A/D Converter) Input sensitivity 0.15 μV/d or greater (d = min

Pagina 56

AD-4430B - 7 - 3.3.2. Weighing Function Zero adjustment Sets the gross weight to zero by pressing the (ZERO) key. Selection of disable or en