A&D OP-04 Especificaciones

Busca en linea o descarga Especificaciones para De medición, control y control A&D OP-04. A&D OP-04 Product specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Weighing Indicator

Weighing Indicator for Check Weighing Scales 1WMPD4002313

Pagina 2 - This Manual and Marks

8 5. NAMES AND FUNCTIONS No. NAMES FUNCTIONS / OPERATION WEIGHT DATA DISPLAY Indicates the weight data.

Pagina 3

9 No. NAMES FUNCTIONS / OPERATION COMPARISON INDICATORS Indicates the results of the weight comparison LO (RED), OK (GREEN) and HI (YELLOW).

Pagina 4 - 1. COMPLIANCE

10 6. FUNCTION PARAMETER SETTINGS To design a platform scale, set the capacity, weighing unit and other functions according to the specification

Pagina 5 - 2. INTRODUCTION

11 6-2. Function list Item Function number Description  C01- 0 CAL switch enabled, 0 key enabled C01- 1 CAL switch disabled, 0 key

Pagina 6 - 3. UNPACKING

12 7. CALIBRATION This function adjusts the scale (indicator) for accurate weighing. Calibration must be done when the FS-D is initially connect

Pagina 7 - 4-2. Load Cell Connections

13  If you need ZERO calibration but do not need SPAN calibration, turn the power off to exit from the calibration procedure. 7. To calibrate wi

Pagina 8 - Example of calculation:

14 8. AUTO-TARE FUNCTION The FS-D has an auto-tare function to be used with the comparator function enabled. If the weight value is within the OK

Pagina 9

15 9. ADDITIONAL INFORMATION This section describes the additional functions and corrections to the instruction manual of FS-i series (WM+PD40013

Pagina 10 - 5. NAMES AND FUNCTIONS

16 The frame ground and the shield are connected internally and there is no difference between them in use. Data format  Example of data Out of

Pagina 11

17 Command H I , + 0 0 1 0 0 CRLF Assume 2 decimal place number. Reply H I , + 0 0 1 0 0 CRLF 1.00% will be set as LO limit %. Command L O

Pagina 12

This Manual and Marks All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard

Pagina 13 - 6-2. Function list

18 10. ERROR MESSAGES Overload error Warning to indicate that an object beyond the weighing capacity has been placed on the weighing pan. Remove

Pagina 14

19 11. SPECIFICATIONS 11-1. Capacity and minimum display C02- setting 0* 1 2 3 4 5 6 7 Capacity 6 15 30 60 150 300 600 1500 0.002* 0.005 0.01 0

Pagina 15 - -009.8050

20 11-3. Options OP-02 (HC-02i) SLA Battery (Yuasa Battery NP4-6 recommended.) OP-03 (FS-03i) RS-232C + Comparator Relay Output (See note.) OP-04

Pagina 17 - 9. ADDITIONAL INFORMATION

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 A&D ENGINEERING, IN

Pagina 18 - Data output mode (f06)

1 Contents 1. COMPLIANCE ... 2 2. INTRODUCTION ...

Pagina 19 - 9-3. OP-04 RS-422 / 485

2 1. COMPLIANCE Compliance with FCC rules  Please note that this equipment generates, uses and can radiate radio frequency energy. This equipme

Pagina 20

3 2. INTRODUCTION This manual describes how this product works and how to get the most out of it in terms of performance. The FS-D weighing indi

Pagina 21 - 11. SPECIFICATIONS

4 3. UNPACKING Unpack the indicator carefully and keep the packing material if you are likely to transport the indicator again in the future. W

Pagina 22 - 11-4. Dimensions

5 4. INSTALLATION and PRECAUTIONS 4-1. Precautions for Installing the Indicator  Ground the indicator so that the user will not be subjected an

Pagina 23

6 Setscrew BSetscrew A 4. Solder the wires to the pin contacts of the connector.  A 5 m or less load cell cable is recommended as the FS-D uses

Pagina 24 - BackCover 1WMPD4000058J

7 4-4. Setting Up the Indicator  Connect the main power cord to an outlet that has an earth ground terminal. You may use the ear

Comentarios a estos manuales