Meaning of the DriverP0 parameter:
Indicates the station address (0-9).
Meaning of the DriverP1 parameter:
6
Write All Setpoint Parameters
Description of this command:
Allows you to set the Final Weight, Free Fall, Preliminary Output, Over, Under, Optional
Preliminary and Zero Band parameters.
Methods used to run this command:
Analog Output
Number of points accepted by this command:
7
Meaning of the DriverP0 parameter:
Indicates the station address (0-9).
Meaning of the DriverP1 parameter:
7
Values that are sent:
Value in PointValue (0) = Final Weight.
Value in PointValue (1) = Free Fall.
Value in PointValue (2) = Preliminary Output.
Value in PointValue (3) = Over Weight.
Value in PointValue (4) = Under Weight.
Value in PointValue (5) = Optional Preliminary.
Value in PointValue (6) = Zero Band.
Write Setpoint Parameters
Description of this command:
Allows you to set the Final Weight, Free Fall, Preliminary Output, Over and Under Weight
parameters.
Methods used to run this command:
Analog Output
Number of points accepted by this command:
5
Meaning of the DriverP0 parameter:
Indicates the station address (0-9).
Meaning of the DriverP1 parameter:
8
Meaning of the DriverP2 parameter:
Indicates the Code Number (0-99).
Values that are sent:
Value in PointValue (0) = Final Weight.
Value in PointValue (1) = Free Fall.
Value in PointValue (2) = Preliminary Output.
Value in PointValue (3) = Over Weight.
Value in PointValue (4) = Under Weight.
Set Accessories
Description of this command:
Allows you to set the Optional Preliminary and Zero Band parameters.
Methods used to run this command:
Analog Output
Number of points accepted by this command:
2
Meaning of the DriverP0 parameter:
Indicates the station address (0-9).
Meaning of the DriverP1 parameter:
9
Values that are sent:
Value in PointValue (0) = Optional Preliminary.