Page 48 AD-4402
7.3.5.
7.3.5.7.3.5.
7.3.5. Discharge
DischargeDischarge
Discharge
S
SS
Sequence
equenceequence
equence
The discharge sequence is used to discharge the material from the hopper and clear
the hopper after finishing a batch weighing.
Concerning Parameters of the Function
Storing the time between receiving a start command and opening the discharge gate.
[5q f-38]
[Function] - [Function setting] - [Sequence] - [Timer] - [
Discharge start
delay timer
]
Using the alarm for the discharge time limit.
[5q f-39] If it is over, an error SQ.ERR 7 is displayed.
[Function] - [Function setting] - [Sequence] - [Timer] - [
Discharge
monitoring timer
]
Storing the time between cleared hopper and closing the gate.
[5q f-40]
[Function] - [Function setting] - [Sequence] - [Timer] - [
Discharge gate
close delay timer
]
Discharging it automatically when the weighing is finished.
[5q f-14] When the finish signal is turned off, the discharge start timer starts.
[Function] - [Function setting] - [Sequence] - [Control] - [
Batch finish
action
]
Discharging it automatically when the mixing weighing is finished.
[5q f-17] When the finish signal is turned off, the discharge start timer starts.
[Function] - [Function setting] - [Sequence] - [Control] - [
Recipe finish
action
]