7.2.
7.2.7.2.
7.2. Batch
BatchBatch
Batch Weighing Mode
Weighing Mode Weighing Mode
Weighing Mode
This mode is used to get a (constant) final weight from a supplying hopper for the
hopper scale and filling machine. And mode can be classified as normal batch
weighing or loss-in-weigh.
There are two control methods of the customer programmed control and built-in
automatic program mode.
Normal Batching
Normal batch weighing weighs the material charged into the hopper.
Control gates (valves) can be used. (Full flow, medium flow and dribble flow)
Loss-in-weigh
Loss-in-weigh weighs the material discharged from the hopper.
Control gates (valves) can be used. (Full flow, medium flow and dribble flow)
Caution
Use PLC (programmable logic controller unit) to supply material into the
weighing hopper and monitor the bulk of material in the hopper.