2.8.2 Displaying blocks and files from a S7
The "Component blocks" menu displays the content of the project in the case of S7
CPU objects.
You obtain the details about the particular block with the right mouse button. You
can open the selected block or display its properties.
2.8.3 Transferring the configuration to new hardware
Proceed as follows to transfer configuration data to new hardware:
1. Select an "S7" component.
2. Select "Transfer the configuration to new hardware" in the context menu.
ADDM then lists all accessible nodes.
3. Select a target CPU and click on "OK".
The program block is transferred to the selected component.
4. If an S7 CPU is exchanged, the data is transferred to the "CPU address"
configured in the "Offline project". If the address stored there is not the
default address 2, then ADDM issues an error message.
Danger
Use the "Transfer the configuration to new hardware" function very carefully. It
overwrites the configuration settings on the target component.